KEY FINDINGS: In 203 nulliparous women assessed at 35+0 to 36+6 weeks, higher sFlt-1/PlGF ratios were associated with higher OA-PSV ratios, lower OA-PI, and higher MAP. An OA-PSV ratio 0.61 identified women with an sFlt-1/PlGF ratio <38 with 90.5% accuracy at a 15% false-positive rate. The findings suggest that OA Doppler, particularly the PSV ratio, may provide a noninvasive and accessible surrogate for angiogenic imbalance near term. Further validation is needed before OA Doppler can replace biochemical assessment in clinical practice.
BACKGROUND: Angiogenic imbalance, reflected by an elevated soluble fms-like tyrosine kinase-1 to placental growth factor (sFlt-1/PlGF) ratio, is associated with the pathophysiology of pre-eclampsia. Although the sFlt-1/PlGF ratio can help identify angiogenic imbalance, its use may be limited by cost and availability. This study evaluated whether ophthalmic artery (OA) Doppler parameters are associated with the sFlt-1/PlGF ratio and whether OA Doppler could help identify or exclude angiogenic imbalance in near-term pregnancy.
DETAILS: This cross-sectional cohort study was nested within the PE37 randomized controlled trial and included nulliparous women recruited between January 2023 and January 2025. Women underwent sFlt-1/PlGF measurement between 35+0 and 36+6 weeks' gestation. A subsample underwent OA Doppler assessment, including the OA peak systolic velocity (PSV) ratio and pulsatility index (PI), together with measurement of mean arterial pressure (MAP) and mean uterine artery PI. The Doppler operator was blinded to the sFlt-1/PlGF results. The analysis included 203 women, distributed across the lowest, middle, and highest sFlt-1/PlGF ratio tertiles as 62, 71, and 70 women, respectively.
Increasing sFlt-1/PlGF ratio was associated with progressive changes in OA Doppler measurements. The median OA-PSV ratio increased from 0.45 (IQR, 0.39–0.53) in the lowest tertile to 0.48 (IQR, 0.41–0.58) in the middle tertile and 0.59 (IQR, 0.50–0.66) in the highest tertile (adjusted P<0.001). Conversely, median OA-PI decreased from 2.20 (IQR, 1.92–2.61) to 2.13 (IQR, 1.86–2.37) and 1.86 (IQR, 1.60–2.26), respectively (adjusted P=0.031).
MAP also increased across the sFlt-1/PlGF tertiles, from 87.0 (IQR, 82.7–92.0) mmHg to 88.7 (IQR, 83.7–93.7) mmHg and 94.7 (IQR, 89.3–100.0) mmHg (adjusted P<0.001). In contrast, mean uterine artery PI did not demonstrate a significant trend across the sFlt-1/PlGF tertiles.
For identifying an sFlt-1/PlGF ratio <38, an OA-PSV ratio <0.61 correctly identified 90.5% of women at a 15% false-positive rate. The authors therefore identified OA Doppler, particularly the PSV ratio, as a potentially useful surrogate measure for angiogenic imbalance and a promising approach for ruling out abnormal angiogenic status.
Copyright © Skyscape. All rights reserved.
Source: Tinajero, M. F., Faraci, C., Cuenca, M., et al. Ophthalmic artery Doppler as potential surrogate marker of angiogenic imbalance in near-term pregnancy. Ultrasound in Obstetrics & Gynecology. 2026; 68(2):211–219. Published: August, 2026. DOI: 10.1002/uog.70270.